Article no.
Product
Primary current
Secondary current
Performance
Cable opening diameter
Copper rail Dimension max
Manufacturer Type
Mechanical Design
Accuracy class
Field of application
Charging connection
Charging power
Charging station type
Communication
Installed components
Manufacturer
Rated current
Accessories Function
Overvoltage category
Display and operation
Multimeter Main functions
Special features Multimeter
Maximum voltage measurement
Maximum current measurement
Comfort functions
Cable length
RX.50-21-150
Stromwandler RX 50/21 (150/5A) Leistung 2,5VA - KL.0,5
150 A
5 A
2.50 VA
21 mm
20 x 10 mm
Optec RX
Inseparable
0,5 %
RX.50-30-150
Stromwandler RX 50/30 (150/5A) Leistung 3,75VA - KL.1
150 A
5 A
3.75 VA
26 mm
30 x 10 mm
Optec RX
Inseparable
1,0 %
HT.IRONMETER
Digitalmultimeter TRMS mit 4 stellige Anzeige - Sturzsicher bis 3m
CAT-III 600 V
LCD display
Rotary selector switch
Function keys
Rotary selector switch
Function keys
AC alternating voltage
AC Alternating current
DC direct voltage
DC Direct current
TRMS effective value
Buzzer continuity test
Diode test
Frequency
Capacity
Resistance
AC Alternating current
DC direct voltage
DC Direct current
TRMS effective value
Buzzer continuity test
Diode test
Frequency
Capacity
Resistance
Extremely robust/shock-resistant
AC up to 600 V
DC up to 600 V
DC up to 600 V
AC up to 10 A
DC up to 10 A
DC up to 10 A
Backlight
Car range
Automatic shutdown
Data HOLD function
MIN/MAX function
Car range
Automatic shutdown
Data HOLD function
MIN/MAX function
P.354266
Ladekomponente zur Entity PRO 22 kW 4m
Apartment building
Public area
Employee parking spaces
Public area
Employee parking spaces
1x smooth cable with type 2 plug
22 kW
Wallbox (wall mounting)
WLAN module
Ethernet 10/100 TX
4G modem
OCPP (Open Charge Point Protocol)
Ethernet 10/100 TX
4G modem
OCPP (Open Charge Point Protocol)
RFID card reader
DC residual current detection
Energy meter (not MID)
DC residual current detection
Energy meter (not MID)
Garo
32 A (AC3P)
4 meter smooth cable
RX.50-21-250
Stromwandler RX 50/21 (250/5A) Leistung 5VA - KL.0,5
250 A
5 A
5.00 VA
21 mm
20 x 10 mm
Optec RX
Inseparable
0,5 %
RX.50-21-200
Stromwandler RX 50/21 (200/5A) Leistung 3,75VA - KL.0,5
200 A
5 A
3.75 VA
21 mm
20 x 10 mm
Optec RX
Inseparable
0,5 %
RX.140-80-1000
Stromwandler RX 140/80 (1000/5A) Leistung 10VA - KL.0,2
1000 A
5 A
10.00 VA
73 mm
2x 60 x 10 mm
2x 80 x 10 mm
2x 80 x 10 mm
Optec RX
Inseparable
PRI.9011122
Prilogy PRI.Charger Wallbox 1x 22kW
Detached house
Apartment building
Semi-public area
Public area
Employee parking spaces
Apartment building
Semi-public area
Public area
Employee parking spaces
1x type 2 charging socket
22 kW
Wallbox (wall mounting)
WLAN module
Ethernet 10/100 TX
OCPP (Open Charge Point Protocol)
Ethernet 10/100 TX
OCPP (Open Charge Point Protocol)
RFID card reader
DC residual current detection
Energy meter (not MID)
DC residual current detection
Energy meter (not MID)
Prilogy
32 A (AC3P)
PRI.9111122-4G
Prilogy PRI.Charger Wallbox 1x 22kW 4G
Detached house
Apartment building
Semi-public area
Public area
Employee parking spaces
Apartment building
Semi-public area
Public area
Employee parking spaces
1x type 2 charging socket
22 kW
Wallbox (wall mounting)
WLAN module
Ethernet 10/100 TX
4G modem
OCPP (Open Charge Point Protocol)
Ethernet 10/100 TX
4G modem
OCPP (Open Charge Point Protocol)
DC residual current detection
Energy meter (not MID)
Energy meter (not MID)
Prilogy
32 A (AC3P)