The Rogowski coil is used to measure AC currents and is primarily intended for retrofitting into existing systems. The output signal from the Rogowski coil is fed to a transducer, which outputs a standardized AC current of up to 1 A.

Technical specifications are guaranteed only when used in combination with the Janitza RogoTrans transducer 15.03.646


  • Accuracy class 0.5, in accordance with IEC 61869
  • Operating temperature: –40°C to +80°C
  • Rated insulation voltage: 1 kV CAT III
  • High linearity – no saturation – no current limiting
  • Phase-accurate detection of harmonics and transients
  • Retrofittable and flexible Rogowski current transformers
  • AC currents from 1–8000 A can be detected
  • For use with Janitza UMGs (except UMG20CM)
  • Immediate detection of load changes
  • Easy installation even with large cable diameters
  • Space-saving, compact, and handy
  • Installation without dismantling system components
  • Secure fit on busbars and round conductors

Rogowski coil – a thin, lightweight flexible current transformer designed for easy installation.

Retrofit installation of current transformers without power interruption, even at high currents.


The Rogowski coil is used to measure AC currents and is primarily intended for retrofitting in existing systems—either on busbars or on power cables. Retrofitting around the primary conductor is possible because the Rogowski coil can be split open.
Filter
Primary current
Cable opening diameter
Primary current
Cable opening diameter

Filter

Primary current
Cable opening diameter
Reset filter

Rogowski Spulen

The Rogowski coil is used to measure AC currents and is primarily intended for retrofitting into existing systems. The output signal from the Rogowski coil is fed to a transducer, which outputs a standardized AC current of up to 1 A.

Technical specifications are guaranteed only when used in combination with the Janitza RogoTrans transducer 15.03.646


  • Accuracy class 0.5, in accordance with IEC 61869
  • Operating temperature: –40°C to +80°C
  • Rated insulation voltage: 1 kV CAT III
  • High linearity – no saturation – no current limiting
  • Phase-accurate detection of harmonics and transients
  • Retrofittable and flexible Rogowski current transformers
  • AC currents from 1–8000 A can be detected
  • For use with Janitza UMGs (except UMG20CM)
  • Immediate detection of load changes
  • Easy installation even with large cable diameters
  • Space-saving, compact, and handy
  • Installation without dismantling system components
  • Secure fit on busbars and round conductors

Rogowski coil – a thin, lightweight flexible current transformer designed for easy installation.

Retrofit installation of current transformers without power interruption, even at high currents.


The Rogowski coil is used to measure AC currents and is primarily intended for retrofitting in existing systems—either on busbars or on power cables. Retrofitting around the primary conductor is possible because the Rogowski coil can be split open.