Residual current monitoring SmartDetect RCMS
Bender

Residual current monitoring SmartDetect RCMS

The LINETRAXX SmartDetect RCMS410/RCMS425-L/RCMS425-D is a measuring device for monitoring differential currents in grounded power supply networks. It can monitor 4 measuring channels simultaneously and measures differential currents between 2 mA and 70 A at DC voltage and in a frequency range of 0 Hz to 100 Hz. power supply networks. It can monitor 4 measuring channels simultaneously and measures differential currents between 2 mA and 70 A at DC voltage and in a frequency range from 15 Hz to 20 kHz AC voltage.


Type selection


TypeDisplayIOs RelayPower supply

RCMS410

LED bar graph

M+, Q, I

DC 24 V

RCMS425-L

LED bar graph

M+, Q, I; K1, K2

DC 24 V; AC/DC 100...240 V

RCMS425-D

TFT display

M+, Q, I; K1, K2

DC 24 V; AC/DC 100...240 V



LED bar graph with (RCMS410, RCMS425-L)

  • Device status LED
  • LEDs for warning and main alarm
  • Alarm LEDs per channel


TFT display (RCMS425-D)

  • Device status LED
  • Alarm LED
  • Full-text menu
  • 4-button navigation


Function modules: 

  • A: Harmonic analysis (FFT)  
  • B: All-current-sensitive measurement for use with current transformer series type B/B+
  • C: External transformer connection type A



Main features Applications Technical data
  • 4 channels in a compact housing
  • Alternating, pulse, and/or all-current sensitive measurement per channel
  • Analysis of harmonics up to the 400th harmonic
  • Adjustable frequency response
  • Communication via various interfaces
  • Measuring and evaluating differential, fault, and rated currents of consumers and systems
  • Monitoring the differential currents of stationary electrical systems and equipment as an alternative to RIso testingin accordance with accident prevention regulation DGUV V3 and industrial safety regulation BetrSichV
  • Detecting gradual deterioration of insulation supports preventive maintenance
  • Monitoring of fire-hazardous currents in fire-prone operating facilities
  • EMC monitoring of TN-S systems for "stray" currents and additional N-PE bridges
  • Monitoring of PE and PA conductors for freedom from current
  • Monitoring of N conductors for overload due to harmonics
  • Monitoring of digital inputs

LINETRAXX SmartDetect RCMS410

Article no.
Type
Response value lΔn2
functional modules
Interface
alarm
B.84604040
RCMS410
RCMS410
6mA...30A
Customized
Modbus RTU (RS-485)
digital output
B.84604041
RCMS410
RCMS410
10mA...10A
B
Modbus RTU (RS-485)
digital output
B.84604042
RCMS410
RCMS410
6mA...30A
A / B / C
Modbus RTU (RS-485)
digital output

LINETRAXX SmartDetect RCMS425-L

Article no.
Type
Response value lΔn2
functional modules
Interface
alarm
B.84605040
RCMS425-L
RCMS425-L
6mA...30A
Customized
Modbus RTU (RS-485)
Relays K1 and K2
B.84605041
RCMS425-L
RCMS425-L
10mA...10A
B
Modbus RTU (RS-485)
Relays K1 and K2
B.84605042
RCMS425-L
RCMS425-L
6mA...30A
A / B / C
Modbus RTU (RS-485)
Relays K1 and K2

LINETRAXX SmartDetect RCMS425-D

Article no.
Type
Response value lΔn2
functional modules
Interface
alarm
B.84606040
RCMS425-D
RCMS425-D
6mA...30A
Customized
Modbus RTU (RS-485)
Relays K1 and K2
B.84606041
RCMS425-D
RCMS425-D
10mA...10A
B
Modbus RTU (RS-485)
Relays K1 and K2
B.84606042
RCMS425-D
RCMS425-D
6mA...30A
A / B / C
Modbus RTU (RS-485)
Relays K1 and K2