MID energy meter

A MID energy or electricity meter measures the energy or electricity consumed within a predefined time period in kilowatt-hours (kWh). Thanks to automatic electronics integrated directly into the meter, the current flow and voltage are measured. Based on these values, the energy meter calculates electricity consumption, which can then be read on the display. This allows managers of self-consumption communities (EVG), shopping centers, airports, hotels, apartment buildings, office buildings, and other commercial properties to accurately track electricity consumption. This achieves two goals: Precise measurement ensures that energy consumption can be allocated to individual tenants or consumption points. Furthermore, sources of energy waste are identified, allowing for the reduction of unwanted energy consumption and an increase in efficiency.

Totaling Comparison (German)

Totaling Comparison (French)

Total Comparison (Italian)

Totals Comparison (English)

Calculation Example (Excel—German)


Selection Criteria

Sum of Amounts

Vector Summation


Includes cos(φ)

Yes

Yes


MID certified

yes

yes


Class 1 for active energy

Yes

Yes


Offsetting of energy consumers and generators on the same register

No

yes

  • Direct connection up to 80 A or transformer connection (M3PRO)
  • Password-protected access
  • Illuminated display
  • M-Bus EN13757 / Modbus RTU integrated (or optional)
  • Dual tariff T1 / T2 4-quadrant measurement
  • Class 1 for active energy, MID-tested
  • Installation width 72 mm, DIN mounting (M3PRO)
  • Sealed terminal cover
  • All measured values can be read out

Summation by Amount vs. Vector Summation:


The VSE has published a mandatory calculation guideline for the smart meter rollout: “Vector summation must be used for smart meter rollouts.”

​A distinction is made between vector summation (Mode A) and absolute value summation (Mode B):​

Vector summation (Mode A):​
- For end consumers only > preferred​

- For end consumers with additional feed-in > required​
​
Absolute value summation (Mode B):​
- For end consumers only > possible​
- For end consumers with additional feed-in > not permitted​

​


Filter
Connection
Number of phases
Interface
Summation method
Series
Connection
Number of phases
Interface
Summation method
Series

Filter

Connection
Number of phases
Interface
Summation method
Series
Reset filter

MID energy meter

A MID energy or electricity meter measures the energy or electricity consumed within a predefined time period in kilowatt-hours (kWh). Thanks to automatic electronics integrated directly into the meter, the current flow and voltage are measured. Based on these values, the energy meter calculates electricity consumption, which can then be read on the display. This allows managers of self-consumption communities (EVG), shopping centers, airports, hotels, apartment buildings, office buildings, and other commercial properties to accurately track electricity consumption. This achieves two goals: Precise measurement ensures that energy consumption can be allocated to individual tenants or consumption points. Furthermore, sources of energy waste are identified, allowing for the reduction of unwanted energy consumption and an increase in efficiency.

Totaling Comparison (German)

Totaling Comparison (French)

Total Comparison (Italian)

Totals Comparison (English)

Calculation Example (Excel—German)


Selection Criteria

Sum of Amounts

Vector Summation


Includes cos(φ)

Yes

Yes


MID certified

yes

yes


Class 1 for active energy

Yes

Yes


Offsetting of energy consumers and generators on the same register

No

yes

  • Direct connection up to 80 A or transformer connection (M3PRO)
  • Password-protected access
  • Illuminated display
  • M-Bus EN13757 / Modbus RTU integrated (or optional)
  • Dual tariff T1 / T2 4-quadrant measurement
  • Class 1 for active energy, MID-tested
  • Installation width 72 mm, DIN mounting (M3PRO)
  • Sealed terminal cover
  • All measured values can be read out

Summation by Amount vs. Vector Summation:


The VSE has published a mandatory calculation guideline for the smart meter rollout: “Vector summation must be used for smart meter rollouts.”

​A distinction is made between vector summation (Mode A) and absolute value summation (Mode B):​

Vector summation (Mode A):​
- For end consumers only > preferred​

- For end consumers with additional feed-in > required​
​
Absolute value summation (Mode B):​
- For end consumers only > possible​
- For end consumers with additional feed-in > not permitted​

​