Verdrosselte Kompensationsanlagen ES
Choked Reactive Power Compensation (Harmonic Filter) in ES8206 Plug-in Design.
We would be happy to consult with you at your location or on-site regarding solutions for managing reactive power and filtering options.
- Minimal grid interference – stabilization of the grid voltage
- Reduction of harmonic load
- Long service life thanks to a robust cooling system and top-quality components
- Maximized operational reliability through optimized thermal design and top-tier components
- Low losses thanks to high-quality power capacitors
- Minimized grid disturbances through power semiconductors
- BLK Control System in a Steel Cabinet (Floor-Mounted)
- Rated voltage: 400 V, 3-phase, 50 Hz
- Choke: 7% (189 Hz series resonance frequency)
- Choke: 14% (134 Hz series resonance frequency)
- Protection class: IP32
- For units 120 kvar and above, forced ventilation via fan
- With Prophi® 6R / 12R reactive power controller
- Commercial and Industrial Facilities with Inductive Loads
Manufacturing facilities with high electricity consumption
Distribution systems requiring power factor correction
Energy centers, equipment rooms, main distribution panels
Retrofitting in existing facilities or as part of new installations
- Applications with rapid and high load changes
- Automatically controlled central compensation in the NSHV
- For use in networks with harmonic loads
- Power converter capacity (non-linear loads)
- >15% of the connected load
- Total harmonic distortion (THD-U) > 3%
- Harmonic filtering and improvement of voltage quality
- Reduction of reactive power costs
- Stabilization of the line voltage
Filter
Reset filterVerdrosselte Kompensationsanlagen ES
Choked Reactive Power Compensation (Harmonic Filter) in ES8206 Plug-in Design.
We would be happy to consult with you at your location or on-site regarding solutions for managing reactive power and filtering options.
- Minimal grid interference – stabilization of the grid voltage
- Reduction of harmonic load
- Long service life thanks to a robust cooling system and top-quality components
- Maximized operational reliability through optimized thermal design and top-tier components
- Low losses thanks to high-quality power capacitors
- Minimized grid disturbances through power semiconductors
- BLK Control System in a Steel Cabinet (Floor-Mounted)
- Rated voltage: 400 V, 3-phase, 50 Hz
- Choke: 7% (189 Hz series resonance frequency)
- Choke: 14% (134 Hz series resonance frequency)
- Protection class: IP32
- For units 120 kvar and above, forced ventilation via fan
- With Prophi® 6R / 12R reactive power controller
- Commercial and Industrial Facilities with Inductive Loads
Manufacturing facilities with high electricity consumption
Distribution systems requiring power factor correction
Energy centers, equipment rooms, main distribution panels
Retrofitting in existing facilities or as part of new installations
- Applications with rapid and high load changes
- Automatically controlled central compensation in the NSHV
- For use in networks with harmonic loads
- Power converter capacity (non-linear loads)
- >15% of the connected load
- Total harmonic distortion (THD-U) > 3%
- Harmonic filtering and improvement of voltage quality
- Reduction of reactive power costs
- Stabilization of the line voltage