UMG 509-PRO-230V-CH-UL Master Messgerät RCM
Network analyzer with differential current monitoring
Harmonics up to the 63rd harmonic
For TN, TT, and IT networks
Ethernet web server, 256 MB of measurement data storage
The UMG 509-PRO is a high-performance power analyzer with residual current monitoring; it can measure harmonics up to the 63rd harmonic. The analyzer is used at all levels of TN and TT networks, as well as in IT networks, for power quality monitoring, residual current monitoring, and energy data management. It also features a 256 MB measurement data memory and can be programmed graphically using Jasic (PLC functionality). Network interfaces and the open communication architecture with numerous protocols (Modbus, IP) enable easy integration into higher-level systems. At the field level, two digital inputs and two digital outputs, as well as a temperature measurement input, are available.
Pre-installed apps:
· Measurement Value Monitor
· IEC 61000-2-4 Watchdog PRO light
· Push Service PRO (optional, not pre-installed)
Key Features:
· Optec Data Logging Kit (Switzerland)
· Measurement Value Monitor: Graphically presented data on the device’s own homepage without the need for additional software installation
· IEC 61000-2-4 Watchdog PRO light: Continuous monitoring of power quality in accordance with the IEC 61000-2-4 standard in customer power grids
· Push Service PRO: Automatic transmission of measurement data directly from the meter to a cloud service
· Harmonic analysis up to the 40th harmonic, detection of short-term interruptions
· Transient detection, waveform display (current and voltage), unbalance, phasor diagram
· User-friendly, color graphic display with intuitive user guidance
· Ethernet interface and web server
· High flexibility through the use of open standards
· Customized data forwarding via email, activation of digital outputs, etc.
· Communication: Profibus (DP/V0), Modbus (RTU, TCP, gateway), TCP/IP, BACnet (optional)
· Up to 4 ports simultaneously
· HTTP, FTP (file transfer), TFTP, NTP (time synchronization), SMTP (email function), DHCP
· Large measurement data memory (256 MB Flash), 32 MB SDRAM
· Interfaces: Ethernet, Profibus / RS485 (DSUB-9)
· 2 digital inputs
· 2 digital outputs
Communication:
· Protocols: Profibus (DP/V0)
· Modbus (RTU, TCP, gateway)
· TCP/IP
· BACnet (optional)
· HTTP (Homepage)
· FTP (file transfer)
· SNMP
· TFTP
· NTP (time synchronization)
· SMTP (Email)
· DHCP
Interfaces
· Ethernet 10/100TX
· Profibus (DSUB-9)
· RS485 Modbus (terminal block)
Measurement Accuracy
· Operating: Class 0.2S (... / 5 A)
· Current: 0.2%
· Voltage: 0.1%
Device-specific homepage
· Detailed online measurement data without software installation
· Expansion via optional apps
· Voltage quality
·
· Harmonics up to the 63rd harmonic
· Short-term interruptions (20 ms and longer)
· Transient recorder (> 50 µs)
· Inrush currents (> 20 ms)
· Imbalance
Power Systems
· IT, TN, and TT power systems
· 3- and 4-phase power systems
· Up to 4 single-phase power systems
Measurement Data Storage
· 256 MB Flash
· 32 MB SDRAM
PLC functionality
· Graphical programming
· Jasic programming language
· Programming limit values, etc.
2 digital inputs
· Pulse input
· Logic input
· Status monitoring
· HT/NT switching
2 digital outputs
· Pulse output (kWh / kvarh)
· Switching output
· Threshold output
· Logic output
Temperature measurement input
· PT100, PT1000, KTY83, KTY84
RCM – Residual Current Monitoring
· 2 differential current inputs
Grid visualization software
· Free GridVis Essentials
Installation:
· 3-phase, 3- and 4-wire connection, voltage 3x400/230V
· Current transformer programming: ..../5 A,
· Supply voltage: 95–240 VAC / 80–300 VDC
· Dimensions: W 144 x H 144 x D 75 mm