nlage ausfallsicher betreiben: zuverlässige Steuerungssysteme für industrielle Verfügbarkeit

Fail-safe operation of systems

With the LINETRAXX® RCMS150 series
In most cases, insulation faults in TN systems lead to the shutdown of the electrical system. To prevent this, it is important to detect deteriorating measurement values or faults at an early stage. With all-current-sensitive residual current monitoring devices, this is possible all the way down to the final circuit. For this reason, the solution is particularly suitable for systems that must be operated with high availability.

LINETRAXX® RCMS150 series

  • All-current-sensitive measurement data acquisition, Type B
  • Pure DC error evaluation
  • Can be used in very confined spaces
  • RS-485 with Modbus RTU or BMS
  • Data can be visualized

The RCMS150… six-channel residual current monitors are designed to measure DC and AC fault currents in grounded power supply systems. These currents can be caused by insulation faults in loads. Differential currents up to IΔ= 500 mA in a frequency range from DC to 2 kHz can be measured with these devices.

They are suitable for applications with a load current up to 32 A and are therefore particularly intended for monitoring final circuits. Two separately adjustable response thresholds allow for a distinction between pre-alarm and alarm.


LINETRAXX® devices feature an RS-485 interface with either BMS protocol or Modbus RTU. Measurement and alarm values are transmitted via this interface, and parameterization is also possible.


Through individual parameterization, the settings can be adapted to local operating conditions and standards.


Please observe the operating range limits specified in the technical data.

Features

  • Permanent residual current monitoring
  • All-current sensitive residual current monitoring device type B with 6 channels K1...6 (each channel offers 2 measuring channels: 1 x RMS, 1 x DC)
  • Ideal for space-sensitive applications
  • Easy installation on top-hat rail or screw mounting on installation distribution board
  • 2 separately adjustable response values (RMS or DC) per channel
  • Permanent self-monitoring
  • Fully shielded measuring current transformers to prevent interference from disturbing magnetic fields
  • Compatible with Bender gateways of type COM465IP, CP9..
  • RCMS150 (RS-485 interface with BMS protocol)
    - Compatible with RCMS460/490 in the system network
    - Address range 2...90, can be set directly on the device
    - Up to 89 RCMS150s can be used on the bus
  • RCMS150-01 (RS-485 interface with Modbus RTU protocol)
    - Compatible in the system network with other Modbus RTU-capable device series from Bender, including the RCMB300 series and RCMB13...-01
    - Address range 1...99 can be set directly on the device using a snap-in potentiometer
    - Address range 1...247 can be set via the bus
    - Up to 247 RCMS150-01 can be used on the bus

Application

Our RCMS150 series is suitable for measuring direct and alternating currents up to IΔ= 500 mA in a frequency range of DC 0...2 kHz. The monitored circuit is rated with a voltage of 300 V and a load current of 32 A. The device can be used up to 2000 m above sea level.