Stromwandler Trennbar KUW-4.2
- KUW4 up to a maximum diameter of 2 x 42 mm
- Specially designed for digital measuring instruments
- Particularly quick installation
- For use with insulated cables up to a maximum of 2 x 42 mm
- Transformation ratios from 60 to 1000/1 A or 150 to 1000/5 A
- Includes color-coded secondary leads
- Additional protection for the transformer provided by two included UV-resistant cable ties
- Suitable for retrofitting, as the primary circuit does not need to be disconnected
- Ideal for use in confined spaces
- Ambient temperature -10 to +55° C
- Relative humidity 5 to 85 % (no condensation)
- Protection class IP20
- Standard IEC 61869-2
- Thermal rated short-time current 60 x In / 1 s
- Thermal continuous current 100 %
- Rated insulation level 0.72 / 3 / kV
- Rated frequency 50 / 60 Hz
- Insulation current class E (120° C)
- Cable opening For conductors max. Ø 18 / 28 / 42 or 2 x 42 mm
- Secondary cable ... / 1 A: 0.5 mm² ... / 5 A: 1.5 mm²
Cable conversion transformers are intended exclusively for installation on insulated primary circuit conductors (supply cables) in a dry location protected from the elements. Installation is possible without interrupting the primary conductor (i.e., while the system is in operation).

Categories
Filter
Primary current
Secondary current
Accuracy class
Cable length
Manufacturer Type
Filter
Reset filterStromwandler Trennbar KUW-4.2
- KUW4 up to a maximum diameter of 2 x 42 mm
- Specially designed for digital measuring instruments
- Particularly quick installation
- For use with insulated cables up to a maximum of 2 x 42 mm
- Transformation ratios from 60 to 1000/1 A or 150 to 1000/5 A
- Includes color-coded secondary leads
- Additional protection for the transformer provided by two included UV-resistant cable ties
- Suitable for retrofitting, as the primary circuit does not need to be disconnected
- Ideal for use in confined spaces
- Ambient temperature -10 to +55° C
- Relative humidity 5 to 85 % (no condensation)
- Protection class IP20
- Standard IEC 61869-2
- Thermal rated short-time current 60 x In / 1 s
- Thermal continuous current 100 %
- Rated insulation level 0.72 / 3 / kV
- Rated frequency 50 / 60 Hz
- Insulation current class E (120° C)
- Cable opening For conductors max. Ø 18 / 28 / 42 or 2 x 42 mm
- Secondary cable ... / 1 A: 0.5 mm² ... / 5 A: 1.5 mm²
Cable conversion transformers are intended exclusively for installation on insulated primary circuit conductors (supply cables) in a dry location protected from the elements. Installation is possible without interrupting the primary conductor (i.e., while the system is in operation).