B.84606042

RCMS425-D Differenzstrom-Überwachung

Inklusive aktivierte Funktionsmodule A, B und C

4-channel all-current-sensitive differential current monitoring

Measurement range: 2 mA to 70 A, DC up to 20 kHz

Harmonic analysis up to the 400th harmonic

RS-485 interface with Modbus RTU

Compact and high-performance, 4-channel residual current monitor sensitive to DC, AC, and pulsed currents for grounded power supply systems. It measures residual currents between 2 mA and 70 A for DC voltages as well as AC voltages in a frequency range from 15 Hz to 20 kHz, enabling flexible use in a wide variety of applications.

Key Features:


· 4 channels in a compact housing

· Analysis of harmonics up to the 400th harmonic

· Adjustable frequency response


Features and Functions:


· Continuous differential current monitoring

· 4 measurement channels for residual current measurement

· Selectable AC, pulse, or all-current-sensitive measurement

· Continuous connection monitoring of the current transformer

· Separate evaluation of the AC and DC components as well as the root mean square (RMS) value of the differential current is possible

· Selectable overcurrent (standard), undercurrent, or window function per channel

· Each measurement channel can alternatively be configured as a digital input

· Response ranges: 10 mA…10 A (Type B/B+), 6 mA…30 A (Type A/F)

· Frequency range: DC…20 kHz

· Preset function

· Reload function

· Adjustable time delays

· Adjustable frequency response

· Analysis of harmonics up to the 400th harmonic, calculation of the THD value

· One digital input, one digital input/output, and one multifunctional digital/analog output

· Integrated combined test/reset button, connection for external buttons

· One device status LED, two alarm LEDs, and one alarm LED per channel

· RS-485 interface with Modbus RTU (reading measured values/configuration)
-Compatible in a networked system with other Modbus RTU-capable device series from Bender, including the RCMB300 series, RCMS150-01, and RCMB13…-01
-Compatible with Bender gateways of the types COM465IP and CP9…-I
- Up to 247 RCMS410 units can be used on the bus

· NFC interface for parameterization using the Bender Connect app

· Expansion, retrofitting, or modification of functionalities to accommodate changing monitoring requirements

· Complies with DIN EN IEC 62020-1


Compatible current transformer series:

· Type A: CTAC, CTAS, W, WR, WS

· Type F: CTAC

· Type B/B+: CTUB-CTBC, CTBS


Application:

· Measure and evaluate differential, fault, and rated currents of loads and systems

· Monitoring residual currents in stationary electrical systems and equipment as an alternative to RIso testing in accordance with the DGUV V3 Accident Prevention Regulation and the BetrSichV Industrial Safety Regulation

· Detecting gradual deterioration of insulation supports preventive maintenance

· Monitoring of fire-hazardous currents in fire-prone facilities

· EMC monitoring of TN-S systems for “stray” currents and additional N-PE bridges

· Monitoring of PE and PA conductors to ensure they are free of current

· Monitoring of N conductors for overloading due to harmonics

· Monitoring of digital inputs


Supply voltage:

· Connections: +, –, A1, A2

Supply voltage: Us DC 24 V / AC/DC 100…240 V