RCMS490CH-D4-2 Differenzstrom Auswertegerät, mehrkanalig.
Differential current monitoring with 12 measurement channels
Up to 90 devices / 1,080 measurement channels in the system
Selectable sensitivity to alternating, pulsed, or all types of current
Alternative to insulation testing according to DGUV V3
The residual current monitoring system (RCMS system) consists of one or more RCMS460-D/-L or RCMS490-D/-L residual current monitoring devices, which can measure and evaluate fault, residual, and operating currents in grounded power supply systems using the corresponding current transformers. The maximum voltage of the monitored network depends on the rated insulation voltage of the measuring current transformers used in busbar systems or on the cables or conductors installed.
For all-current-sensitive measurement (according to IEC/TR 60755: Type B), the closed-type current transformers of the W…AB series are required. One AN420 or AN110 power supply unit is required for every 6 current transformers of the W…AB series.
For alternating and pulsed currents (according to IEC/TR 60755: Type A), the current transformers of the W… (closed), WR… (rectangular), WS… (splittable), and WF… (flexible) series are used.
The various current transformers can be connected to the measurement channels of the monitoring devices in any combination. Each RCMS460-D/-L and RCMS490-D/-L has 12 measurement channels. A total of up to 90 residual current monitoring devices can be connected via the BMS bus (RS-485 interface with BMS protocol), allowing for the monitoring of up to 1,080 measurement channels (outputs).
The frequency response can be adjusted accordingly for applications in personal, fire, and equipment protection. The measured currents can be analyzed for harmonic distortion.
Key Features:
· Alternative to the DGUV V3 insulation test. For MRCD applications in conjunction with circuit breakers
· Choice of AC, pulse, or all-current-sensitive measurement by selecting the current transformers for each channel
· RCMS490 model with one signal contact per channel
· Analysis of harmonics, DC, and THF
· Adjustable frequency response for personal, fire, and equipment protection
Features and Functions:
· Selectable AC, pulse, or all-current-sensitive measurement by selecting the current transformers for each channel
· True root mean square (r.m.s.) measurement
· 12 measurement channels per unit for differential current measurement or digital input
· Up to 90 RCMS… monitoring devices; 1,080 measurement channels in the system
· Fast parallel polling for all channels
· Response ranges: 10 mA…10 A (0…2000 Hz), 6 mA…20 A (42…2000 Hz), 100 mA…125 A (42…2000 Hz) RCMS…-D4
· Preset function
· Adjustable time delays
· Adjustable frequency response for personal, fire, and equipment protection
· History log with timestamps for 300 data records
· Data logger for 300 data records per channel
· Analysis of harmonics, DC, and THD
· Two alarm relays, each with one changeover contact
· RCMS490 model with one alarm contact per channel
· Selectable operating/standby current and fault memory behavior
· Connection for external reset/test button
· Backlit graphic display (7-segment display) and status LEDs
· Data exchange via BMS bus
· Password protection for device settings
· Continuous monitoring of the current transformer connection
· RoHS-compliant
Technical Specifications:
· Number of measurement channels per device: 12
· Collective alarm relay for all channels: 2x1 changeover contacts
· Alarm relays per channel: 12x1 normally open
· Special firmware suitable for Swiss applications
· External current transformers: Series
· W..., WR..., WS..., (Type A), W...AB series (Type B)
· Dimensions: W 162 x H 90 x D 74 mm
· Power supply: DC 70…276 V / AC 70…276 V / 42…460 Hz
· Error code display
· Harmonic analysis (IÄ, DC, THD)
· History memory for 300 data records
· Data logger for 300 data points per channel
· Internal clock, password, languages: GB, D, F
Applications:
· Measure and evaluate differential, fault, and rated currents of loads and systems in the frequency range 0…2000 Hz (current transformers W…AB) and 42…2000 Hz (current transformers W…, WR…, WS…, WF…)
· Monitoring of fire-hazardous currents in fire-prone facilities
· EMC monitoring of TN-S systems for “stray” currents and additional N-PE bridges
· Monitoring of N conductors for overload due to harmonic distortions
· Monitoring of PE and PA conductors for the absence of current
· Monitoring of residual currents in stationary electrical installations and equipment to determine practical testing intervals in accordance with the Accident Prevention Regulation BGV A3 and the Industrial Safety Ordinance (BetrSichV).
· Personal and fire protection through rapid shutdown
· Monitoring of digital inputs
Mounting position:
According to the technical manual: Display-oriented = horizontal