VMD460CH NA-D-2 Netz- und Anlagenschutz zur Überwachung

der Netzeinspeisung von Erzeugungsanlagen

NA Protection for Power Generation Facilities

ROCOF islanding detection

Compliant with VDE-AR-N 4105, CEI 0-21

RS-485, backlit display

The VMD460 is an external grid and system protection device (NA protection) that disconnects the connection between the public grid and the power generation system by activating coupling switches when limit values are exceeded. If voltage and frequency measurements fall outside the threshold values required by standards, the VMD460’s relays trip. The VMD460 is configurable for multiple functions. The current measurement values are continuously displayed on the LCD. The measurement values that trigger the relays are stored.

Key Features:


· Grid and equipment protection with preset basic programs for country-specific standards and guidelines.

· Islanding detection df/dt (ROCOF) vector jump

· RS-485 interface (data exchange/parameterization/software update)

· Continuous monitoring of phase and neutral voltages

· Remote shutdown via remote control signal receiver


Features and Functions:


· Easy commissioning thanks to preset basic programs for country-specific standards and guidelines

· Single-fault protection

· Monitoring of connected coupling switches (configurable: NC/NO/off)

· Islanding detection df/dt (ROCOF)

· Vector jump

· RS-485 interface (data exchange/parameterization/software update)

· Test function for determining the trip time

· Test button for the trip circuit

· Ability to retrieve the last 300 grid faults with timestamps/real-time clock

· Continuous monitoring of phase and neutral voltages

· Separate reclosing conditions following a threshold violation

· Language selection (German, English, Italian)

· Backlit graphic display

· Password protection for device settings

· Remote shutdown via master control signal receiver

· Sealable housing


Technical Specifications:


· Supply voltage Us: AC/DC 100–240 V / DC 50/60 Hz

· Measurement range: AC 10–520 V

· Rated voltage Un (L-N): AC 0...300 V

· Rated voltage Un (L-L): AC 0...520 V

· Number of relays: 2 x 1 changeover relay (K1, K2)

· Dimensions: W108 x H90 x D74 mm

· Weight: 360 g


Applications:


· Central low-voltage protection

· Independent switching point between a generation system connected in parallel with the grid and the public grid

· Application in accordance with CEI 0-21, VDE-AR-N 4105, BDEW guidelines, C10/11, G59/2, G59/3, G83/2, DIN V VDE V 0126-1-1/A1

· Universally applicable for generation systems to ensure safe grid disconnection


Installation orientation:


As specified in the technical manual: Any orientation