B.91068202

ISO175-42-SS Insulation monitoring device

DC drive systems (IT systems) in electric vehicles Samtec/Molex connector / HS-CAN SAE J1939 interface

Insulation Monitoring for Hybrid and Electric Vehicles

Patented, active measurement method

Measurement even when the high-voltage electrical system is de-energized

CAN bus interface

The ISOMETER iso175 product line is an insulation monitoring device for ungrounded drive systems in hybrid and electric vehicles.


Features

Patented, active measurement method

Insulation measurement, even when the vehicle’s high-voltage electrical system is de-energized

Detection of symmetrical and asymmetrical faults

CAN bus interface

Automatic adaptation to the system’s leakage capacitance (up to 10 µF depending on the profile)

Integrated self-diagnosis (online self-test)

HV connection monitoring (offline self-test)

Continuous monitoring of the ground connection

High-voltage shutdown function


Ordering Information

iso175 customized customer configuration based on template

Change to part number B.91068200 -> customized

Please contact us for order processing

There is NO option to reconfigure the parameters

Suitable for 12 V and 24 V DC systems (supply voltage)

Insulation monitoring of DC insulation faults for ungrounded systems (IT systems) DC 0…1000 V

Continuous measurement of insulation resistance RF_corrected = 0…35 MO (RF_original = 0…50 MO)

Response time = 30 s for insulation resistances = 500 O/volt and network leakage capacitances = 2 µF

Insulation measurement for mains leakage capacitance up to 10 µF possible via parameterization (High Capacity profile)

Insulation measurement also possible when the HV onboard power system is de-energized

Integrated self-diagnostics (online self-test)

HV connection monitoring (offline self-test)

Continuous monitoring of the ground connection

Undervoltage detection

Ground connection can be disconnected

Interfaces:


· Digital output for device error notification (OKHS)

· Alternatively

· HS-CAN interface with the following protocols

· Bender CAN

· CAN-SAE J1939

· All outputs are short-circuit-proof

· Load dump protection up to 58 V

· High-voltage isolation function