B.91068142

IR155-4204 A-Isometer Isolationsüberwachungsgerät

Für ungeerdete DC-Antriebssysteme IT-Systeme in Elektrofahrzeugen

Insulation Monitoring for High-Voltage Systems in Electric Vehicles

Continuous measurement from 0 to 10 MΩ

AC and DC IT systems up to 1,000 V

Suitable for 12-V and 24-V vehicle electrical systems

The ISOMETER IR155-4203/IR155-4204 monitors the insulation resistance between the insulated, active high-voltage conductors of an electric drive system (Un = DC 0…1000 V) and the test ground (vehicle ground > Terminal 31). The patented measurement method monitors the insulation resistance on both the DC and AC sides of an electric drive system. Existing insulation faults are reliably detected, even in the presence of high levels of interference that may be caused by motor control processes (acceleration, energy recovery, etc.).

Key Features:


· Insulation monitoring device for ungrounded DC drive systems (IT systems) in

electric vehicles· Continuous measurement of insulation resistance 0…10 MΩ, threshold values

preconfigured

at the factory·

AC and DC IT systems up to 0…1000

V· Short-circuit-proof driver outputs for fault detection and PWM-encoded

insulation measurement value· Power supply suitable for 12V and 24V systems


Functions and Features:


· Suitable for 12-V and

24-V systems· Automatic

self-test· Continuous measurement of insulation resistance 0…10 MΩ –

Response time < 2 s after power-on for the first determined insulation state (SST)

–

Response time < 20 s for measured insulation resistance (DCP)

· Automatic adaptation to the existing network leakage capacitance (≤1 μF)

· Detection of ground faults and disconnection of

the ground connection· Insulation monitoring of AC and DC insulation faults for ungrounded systems (IT systems) 0…1000

V· Undervoltage detection for voltages below 500 V (factory-set by Bender)

· Short-circuit-proof outputs for:

–

Fault detection (high-side output)

–

Measured value (PWM 5…95%) and status (f = 10…50 Hz) for high-side or inverted low-side drivers (MHS/MLS output)

· Protective coating (SL 1301ECO-FLZ)



Technical Specifications:


Supply voltage Us: DC 0...36V
Max. operating current Is: 150 mA
Max. current Ik: 2 A / 6 A/2 ms inrush current
HV voltage range (L+/L-) Un:
AC 0…1000 V (peak value)

0…660 V rms (10 Hz…1 kHz)

DC 0…1000

V Response value: 100 kOhm
Fave:

10 Undervoltage detection: 0 V (inactive)
Measurement output: High-side

Application:

Monitoring for ungrounded DC drive systems (IT systems) in electric vehicles