iso685W-S-P Isolationsüberwachungsgerät
Insulation monitoring for IT systems in accordance with IEC 61557-8
Version without display; operated via FP200
Option W for extreme climatic conditions
Integrated web server and Modbus TCP/RTU
The ISOMETER iso685 is an insulation monitoring device for IT systems in accordance with IEC 61557-8. It can be used universally in AC, 3(N)AC, AC/DC, and DC systems. In AC systems, there may also be extensive DC-powered system components (e.g., power converters, inverters, controlled drives).
iso685-S:
The iso685-S model has no display and no control unit. It can only be used in
combination with the FP200 and is operated indirectly through it.
Parameterization can be performed via a web browser or a COM465.
“W” Option
Optionally, the device variants are available in the “W” option for extreme climatic and
mechanical stresses.
Key features:
· Predefined measurement profiles
· Reliable measurement of insulation resistance, voltage, capacitance, and frequency
· Integrated web server
· Modbus TCP/RTU
· Insulation fault detection
Features and Functions:
iso685-…-P
· ISOMETER® for IT AC systems with galvanically isolated rectifiers or inverters and for IT DC systems (IT = isolated systems)
· Automatic adaptation to the existing network leakage capacitance
· Combination of and other profile-dependent measurement methods
· Two separately adjustable response value ranges from 1 kÙ…10 MÙ
· Connection monitoring (monitoring of the test leads)
· High-resolution graphical LCD display
· Graphical representation of insulation trends over time (isoGraph)
· Automatic display dimming (submarine mode)
· Automatic device self-test
· History memory with real-time clock (3-day buffer) for storing up to 1,023 alarm messages with date and time
· Current or voltage output 0(4)…20 mA, 0…400 µA, 0…10 V, 2…10 V (galvanically isolated), proportional to the measured insulation value of the circuit
· Freely programmable digital inputs and outputs
· Ethernet interface with BCOM, Modbus TCP/RTU, and HTTP protocols
· RS-485/BS (Bender Sensor Bus) for data exchange with other Bender components using the Modbus RTU protocol
· Remote configuration via the Internet or intranet (web server/option: COMTRAXX® Gateway)
· Remote diagnostics via the Internet (only by Bender Service)
· ISOnet: Internal isolation of the ISOMETER® from the IT system being monitored (e.g., when multiple IT systems are interconnected)
· ISOnet Priority: Permanent priority for a device within the network
· ISOloop: Special function for ring networks (all networks are interconnected).
· isoData: Permanent, uninterrupted data transmission
· Test current generation for selective insulation fault detection
· Display of insulation faults selectively located by EDS systems
· Configuration of EDS systems
· EDSsync: Synchronous distribution of EDS trigger information in interconnected networks
· Custom texts for each measurement channel
EDS44x
· Insulation fault detection in AC, 3AC, and DC IT systems
· Up to 12 W, WR, and WS series current transformers can be connected
· Response sensitivity for insulation fault detection: EDS440 2…10 mA, EDS441 0.2…1 mA
· Response sensitivity for differential current measurement: EDS440 100 mA…10 A, EDS441 100 mA…1 A
· Component communication via BS-Bus (RS-485) or BB-Bus
Technical Features:
· For integrated IT systems and with a display for front-panel mounting (FP200)
· Supply voltage Us: AC 100…240 V - DC 120…240 V
· Frequency range Us: 50 Hz, 60 Hz
· Monitored IT system:
· - Nominal line voltage Un: AC 0…690 V (0…600 V UL)
· - Nominal line voltage Un: DC 0…1000 V (0…600 V UL)
· Threshold value Ran1 (Alarm 1): 1 kΩ…10 MΩ (10 kΩ)
· Threshold value Ran2 (Alarm 2): 1 kΩ…10 MΩ (40 kΩ)
· Graphic display, 127 x 127 pixels, 40 mm x 40 mm
· Digital inputs: 3 / Digital outputs: 2
· Analog output: 1
· Interfaces: Ethernet-TCP/IP/HTTP / RS-485 / BMS
· Dimensions: (W x H x D) 107.5 mm x 100 mm x 110 mm
Applications:
· AC, DC, or AC/DC main power circuits
· AC/DC main circuits with directly connected DC components such as power converters, inverters, and controlled drives
· UPS systems, battery networks
· Heating devices with phase-angle control
· Systems with switching power supplies
· IT systems with high leakage capacitance
· Systems with insulation fault detection