iso685W-S-P Isolationsüberwachungsgerät

Alternative zu iso685W-D-P, ohne Display

Insulation monitoring for IT systems in accordance with IEC 61557-8

Version without display; operated via FP200

Option W for extreme climatic conditions

Integrated web server and Modbus TCP/RTU

The ISOMETER iso685 is an insulation monitoring device for IT systems in accordance with IEC 61557-8. It can be used universally in AC, 3(N)AC, AC/DC, and DC systems. In AC systems, there may also be extensive DC-powered system components (e.g., power converters, inverters, controlled drives).

iso685-S:


The iso685-S model has no display and no control unit. It can only be used in

combination with the FP200 and is operated indirectly through it.

Parameterization can be performed via a web browser or a COM465.


“W” Option


Optionally, the device variants are available in the “W” option for extreme climatic and

mechanical stresses.


Key features:


· Predefined measurement profiles

· Reliable measurement of insulation resistance, voltage, capacitance, and frequency

· Integrated web server

· Modbus TCP/RTU

· Insulation fault detection


Features and Functions:


iso685-…-P


· ISOMETER® for IT AC systems with galvanically isolated rectifiers or inverters and for IT DC systems (IT = isolated systems)

· Automatic adaptation to the existing network leakage capacitance

· Combination of and other profile-dependent measurement methods

· Two separately adjustable response value ranges from 1 kÙ…10 MÙ

· Connection monitoring (monitoring of the test leads)

· High-resolution graphical LCD display

· Graphical representation of insulation trends over time (isoGraph)

· Automatic display dimming (submarine mode)

· Automatic device self-test

· History memory with real-time clock (3-day buffer) for storing up to 1,023 alarm messages with date and time

· Current or voltage output 0(4)…20 mA, 0…400 µA, 0…10 V, 2…10 V (galvanically isolated), proportional to the measured insulation value of the circuit

· Freely programmable digital inputs and outputs

· Ethernet interface with BCOM, Modbus TCP/RTU, and HTTP protocols

· RS-485/BS (Bender Sensor Bus) for data exchange with other Bender components using the Modbus RTU protocol

· Remote configuration via the Internet or intranet (web server/option: COMTRAXX® Gateway)

· Remote diagnostics via the Internet (only by Bender Service)

· ISOnet: Internal isolation of the ISOMETER® from the IT system being monitored (e.g., when multiple IT systems are interconnected)

· ISOnet Priority: Permanent priority for a device within the network

· ISOloop: Special function for ring networks (all networks are interconnected).

· isoData: Permanent, uninterrupted data transmission

· Test current generation for selective insulation fault detection

· Display of insulation faults selectively located by EDS systems

· Configuration of EDS systems

· EDSsync: Synchronous distribution of EDS trigger information in interconnected networks

· Custom texts for each measurement channel

EDS44x


· Insulation fault detection in AC, 3AC, and DC IT systems

· Up to 12 W, WR, and WS series current transformers can be connected

· Response sensitivity for insulation fault detection: EDS440 2…10 mA, EDS441 0.2…1 mA

· Response sensitivity for differential current measurement: EDS440 100 mA…10 A, EDS441 100 mA…1 A

· Component communication via BS-Bus (RS-485) or BB-Bus


Technical Features:


· For integrated IT systems and with a display for front-panel mounting (FP200)

· Supply voltage Us: AC 100…240 V - DC 120…240 V

· Frequency range Us: 50 Hz, 60 Hz

· Monitored IT system:

· - Nominal line voltage Un: AC 0…690 V (0…600 V UL)

· - Nominal line voltage Un: DC 0…1000 V (0…600 V UL)

· Threshold value Ran1 (Alarm 1): 1 kΩ…10 MΩ (10 kΩ)

· Threshold value Ran2 (Alarm 2): 1 kΩ…10 MΩ (40 kΩ)

· Graphic display, 127 x 127 pixels, 40 mm x 40 mm

· Digital inputs: 3 / Digital outputs: 2

· Analog output: 1

· Interfaces: Ethernet-TCP/IP/HTTP / RS-485 / BMS

· Dimensions: (W x H x D) 107.5 mm x 100 mm x 110 mm


Applications:


· AC, DC, or AC/DC main power circuits

· AC/DC main circuits with directly connected DC components such as power converters, inverters, and controlled drives

· UPS systems, battery networks

· Heating devices with phase-angle control

· Systems with switching power supplies

· IT systems with high leakage capacitance

· Systems with insulation fault detection