B.95061250

EDGE500IP Condition Monitoring - Gateway

24VDC supply voltage Includes activated feature modules B and C

Condition Monitor with Integrated Gateway

Modbus TCP/RTU, SNMP, and MQTT

Web-based interface without additional software

30 built-in data loggers

The COMTRAXX® EDGE500IP is a high-performance condition monitor with an integrated gateway for centralized monitoring and communication in electrical systems. It connects Bender systems and third-party devices to modern IT and automation networks—securely, flexibly, and with future-proof capabilities. The web-based user interface enables easy commissioning, parameterization, and visualization—without the need for any additional software.

Features:


· Condition monitoring for Bender systems

· Integrated gateway for Modbus TCP/RTU, SNMP, MQTT

· Two physically separate Ethernet interfaces

· HTML5-based web interface

· Device integration via BMS, BCOM, Modbus RTU/TCP

· Digital inputs and outputs for event logging

· Storage, documentation, and restoration of parameters

· Secure remote maintenance via LAN, WAN, or the Internet

· 30 integrated data loggers for continuous recording of system status and errors


Applications:


· Visualization and analysis of device and system statuses

· Monitoring of Bender and third-party devices

· Customized system overviews in a web browser

· Alarm management with targeted user notifications

· Integration into control systems such as building automation

· Commissioning, diagnostics, and remote maintenance of systems


Technical Features:


· Condition Monitor with web interface

· Interfaces for device integration

· BMS bus (internal) with up to 150 devices

· BCOM (up to 255 devices)

· Modbus RTU and Modbus TCP (up to 247 devices each)

· Gateway to Modbus TCP: Reading current measurement values

· and operational/alarm messages from addresses 1–5 of each

· interface via Modbus TCP

· Gateway to Modbus RTU: Reading current measured values

· and operating/alarm messages from addresses 1–5 of the

· internal BMS interface via Modbus RTU

· 2 Ethernet interfaces with 10 Mbit/s | 100 Mbit/s | 1 Gbit/s

· for remote access via LAN, WAN, or the Internet

· Configuration of the EDGE500… device parameters

· Time synchronization for all assigned devices

· 10 data points from third-party devices (via Modbus RTU or

· Modbus TCP) can be integrated into the system

· 8 digital inputs

· Includes Function Modules B and C

· Function module A is available for purchase as an option