de
it
fr
en
Compare
0
Watch list
0
Products
Expertise & projects
Shop
MID energy meter
Janitza UMG power quality measurement devices
Janitza Software und App-Lösungen
Current transformers - separable transformers
e-mobility charging infrastructure
HT measuring and testing devices
Bender insulation monitoring
Bender residual current monitoring
Bender measuring and monitoring relays
Bender hospital technology
Bender measuring current transformer
Bender Unimet medical testing devices
M-Bus components
Janitza UMG mobile measuring case
Insulators
Promotions and campaigns
Stock sale
Other merchandise
Optec
About us
History
Corporate responsibility
Team
Trade fairs & events
Partnerships
Memberships
Sponsoring
Vacancies
News
Downloads
Customer Center
Why Optec
We for you
Contact us
Repair form
Return form
de
it
fr
en
Shop
Bender residual current monitoring
Residual current monitoring RCMS
Residual current monitoring RCMS
Multi-channel AC, pulse and AC/DC sensitive residual current monitoring devices
Filter
close
Reset filter
Net shape
Differential current
Number of measuring channels
Response value lΔn
Alarm relay mode of operation
Alarm relay
Interface
Supply voltage
OK
close
Net shape
select all
remove all
TN / TT
11
IT
3
OK
close
Differential current
select all
remove all
AC Alternating current
11
DC Direct current
11
Pulsating DC
11
All-current sensitive
8
OK
close
Number of measuring channels
select all
remove all
4
3
6
1
12 (per device)
7
12 (Virtual)
1
1080 (per system)
7
OK
close
Response value lΔn
select all
remove all
3 mA...300 mA
1
6 mA...20A
7
10 mA...10 A
10
OK
close
Alarm relay mode of operation
select all
remove all
Quiescent current
7
Working current
7
OK
close
Alarm relay
select all
remove all
2x 1 changeover contact for all channels
7
12x 1 NO contact per channel
3
OK
close
Interface
select all
remove all
RS-485/BMS
8
RS-485/Modbus RTU
3
NFC (Near Field Communication)
3
OK
close
Supply voltage
select all
remove all
AC 16...72 V
2
AC 70...276 V
5
DC 16...94 V
2
DC 24 V
4
DC 70...276 V
5
OK
Filter
Delete filter
Net shape
TN / TT
11
IT
3
Differential current
AC Alternating current
11
DC Direct current
11
Pulsating DC
11
All-current sensitive
8
Number of measuring channels
4
3
6
1
12 (per device)
7
12 (Virtual)
1
1080 (per system)
7
Response value lΔn
3 mA...300 mA
1
6 mA...20A
7
10 mA...10 A
10
Alarm relay mode of operation
Quiescent current
7
Working current
7
Alarm relay
2x 1 changeover contact for all channels
7
12x 1 NO contact per channel
3
Interface
RS-485/BMS
8
RS-485/Modbus RTU
3
NFC (Near Field Communication)
3
Supply voltage
AC 16...72 V
2
AC 70...276 V
5
DC 16...94 V
2
DC 24 V
4
DC 70...276 V
5
B.94053025
RCMS150CH Differenzstrom Auswertegerät
Allstromsensitiv, DC/AC 0..2000Hz 3...300 mA
B.94053002
RCMS460CH-D-2 Differenzstrom Auswertegerät, mehrkanal
Allstromsensitiv, Beleuchtetes Grafikdisplay
B.94053001
RCMS460CH-D-1 Differenzstrom Auswertegerät, mehrkanal
Allstromsensitiv, Beleuchtetes Grafikdisplay
B.94053004
RCMS460CH-L-2 Differenzstrom Auswertegerät, mehrkanal
Allstromsensitiv, 7-Segment-Anzeige und LED-Zeile
B.94053010
RCMS460CH-D4-2 Differenzstrom Auswertegerät, mehrkanalig.
Allstromsensitiv, Beleuchtetes Grafikdisplay
B.94053006
RCMS490CH-D-2 Differenzstrom Auswertegerät, mehrkanal
Allstromsensitiv, Beleuchtetes Grafikdisplay
B.94053005
RCMS490CH-D-1 Differenzstrom Auswertegerät, mehrkanal
Allstromsensitiv, Beleuchtetes Grafikdisplay
B.94053012
RCMS490CH-D4-2 Differenzstrom Auswertegerät, mehrkanalig.
Allstromsensitiv, Beleuchtetes Grafikdisplay
B.84604040
RCMS410-24 Differenzstrom-Überwachung
Werkseinstellungen nach Fertigungsvariante
B.84604041
RCMS410-24 Differenzstrom-Überwachung
Inklusive aktiviertes Funktionsmodul Typ B
B.84604042
RCMS410-24 Differenzstrom-Überwachung
Inklusive aktivierte Funktionsmodule A, B und C
Downloadcenter
Shop
Contact